MIL-T-23588C(OS)
Resolution shall be 0.01 percent of full-scale out-
3.4.9 Resolution.
put.
.3.4.10 Repeatability. Repeatability shall be within 0.1 percent of
full-scale output. Use the average of corresponding data points in a
comparison of two successive pressure cycles. Test in accordance with
4.5.4.7.
With no pressure applied, resistance shall be as
3.4.11 Resistance.
follows :
Input (terminals 3 and k):
247
ohms
plus
or
minus
2
percent
234
ohms
plus
or
minus
2
percent
Output (terminals 1 and 2):
176
ohms
plus
or
minus
2
percent
Between terminals 3 and 1:
Between terminals 3 and 2:
176
ohms
plus
or
minus
2
percent
185
ohms
plus
or
minus
2
percent
Between terminals 4 and 1:
185
ohms
plus
or
minus
2
percent
Between terminals 4 and 2:
3.4.12 Insulation resistance. With 50 volts dc applied, insulation
resistance shall be 300 megohms minimum when tested as specified in
4.5.4.12.
.*
3.5 Environmental requirements. The transducer shall meet all
requirements of this specification during or after the tests defined
or specified in 4.4,
The transducer shall meet the following vibration
3.5.1 Vibration!
requirements:
3.5.1.1 Vibration, nonoperating.e transducer shall. show no damage
Th
*
and shall meet all the performance requirements and product characteris-
tics of this specification after being tested as in 4.4.1.1.
3.5.1.2 Vibration, operating. The transducer shall show no damage and
*
shall meet all the performance requirements and product characteristics
of this specification during and after the test specified in 4.4.1.2.
*
*
3.5.2 Temperature and humidity
3.5.2.1 High temperature and humidity, nonoperating . The transducer
*
shall show no damage and shall meet all the performance requirements and
product characteristics of this specification after being tested as in
4.4.2.1
*